Physical Electronics GmbH

Salzstraße 8
Feldkirchen,  85622

Germany
https://phi-gmbh.eu
  • Booth: B1365


Analytical instruments empowering R&D - DELIVERING VALUE

Matching innovative manufacturers with customers from R&D 

Since 2004, we have been an owner-managed company with three main pillars.

We take over the distribution for niche manufacturers and thus enable small, innovative companies to effectively access the market in Germany, Austria and Switzerland. We also offer customer service for the systems and equipment we sell. Our contract analysis offers you access to our techniques, because it is not always possible to justify an investment.

From the very beginning, we have attached great importance to sustainable and stable growth. This means that we have very close business relationships with all our manufacturers and understand the techniques in detail. We only include manufacturers and products in our portfolio that we are convinced of. You as a customer can rely on us as a dealer. We are your local contact for technical questions, service and everything that is necessary for the long-term operation of the systems.

Complex analytical questions are our daily business. Talk to us and we will find the right technology for you.

Our corporate culture is characterized by a high level of appreciation. Every single employee contributes significantly to the success of our company.


 Products

  • ICSPI nGauge - World’s first AFM-on-a-chip
    The nGauge Atomic Force Microscope (AFM) is an excellent choice for micro- and nano-scale surface analyses for applications such as automotive, aerospace, or electronics....

  • The nGauge from ICSPI is ideal as a complementary technique to typical metallurgical microscopy and can be used to inspect a variety of structural and material properties as well as grinding methodologies. 

    The nGauge enables easy investigation of the thickness of thin films, coatings, and effectiveness of etching procedures, providing the user a significantly richer set of data than profilometry while maintaining the capability to obtain highly precise step height measurements.

    It also determines surface finish, investigates the morphology and characterizes grain structure.

    Capabilities

    • Topography

    • Roughness (Ra)

    • Film thickness

    • Phase imaging (mechanical properties)

    • Particle size

    nGauge  

    Benefits

    • AFM-on-a-chip

    • AFM probe attached to a MEMS chip

    • Integrated piezo resistive sensor (self-sensing)

    • Vertical & lateral actuators (3-axis movement providing high speed scans)

    • Laser-less (no laser alignment)

    • Small & lightweight (vibration resistant)

    • Easy to use (3 clicks for scan)

    • Fast scans (10X faster time-to-data than traditional AFM)

    • Large sample compatibility (100 mm x 50 mm x 18 mm)

  • NeoScan N60 - Compact, accessible micro-CT scanner
    Scientific instrument for X-ray microtomography – an emerging nondestructive 3D imaging technique...

  • FEATURES

    • X-ray source up to 65 kV (For use in polymer, geological, pharmaceutical, bone and dental applications)
    • Spatial resolution of 8 µm (Suitable for most day to day applications)
    • Pixel size of 3.8 µm in full field-of-view of camera (Large format camera without compromising resolution)
    • Low weight and compact design (Fits your desk)
    • Only requires USB3 connection (Works with most laptops, tablets,...)

    Usb3 Flashdrive Neoscan N60

    Non-destructive visualisation of all electronics inside a 128GB USB3 to USB-C flash drive using an N60 desktop microCT scanner.

  • RX Solutions EASYTOM - High-end CT system
    3D X-ray Micro & Nano Measurement and Analysis System. A powerful CT System designed to address the most challenging 3D applications ranging from material research to industrial applications in R&D, quality assurance and production....

  • Virtual sample cut ​

    X-ray CT allows to virtually cut the scanned sample in any orientation for high resolution visualization and analysis of thin slices at any depth​

    One single scan – multiple data​

    One scan allows multiple analyses to be performed: dimensional​ measurements, material characterization, defects analyses and​ inspections of inner structures all in a non-destructive way​

    Inspect and reproduce any assembly ​

    X-ray CT provides a detailed rendering of all the internal and external features. Point clouds representing the surfaces can be extracted allowing parts to be easily reproduced even when CAD models are no longer available​

    X-Ray Computed Tomography (CT) and Digital Radiography (DR) provide interesting results in order to help electronics experts

    Live X-Ray Digital Radiography being available on all RX Solutions systems, it is very easy to detect broken bond wires or identify delamination issues by taking images of a component. The process is non-destructive, can be automated and if the supposed defective connection is not found then the part can be released without any modification. Moreover, preparing a sample to be scanned is no more than finding a support to hold it between the X-Ray tube and the detector.

    Standard microscope inspection is often used in electronics but do not give same results because the majority of its components are hidden under other components, insulation or circuit boards. These superimposed features are not a limitation for X-Ray CT which can provide a three-dimensional model of any electrical connector or chip within a few minutes.

    RX Solutions systems are designed to perform the best X-Ray Computed Tomography available on the market. With such technology electronics experts are now able to distinguish voiding due to gas bubbles in the solders, test Through-Silicon Vias (TSV) and find foreign object debris inside an electronic device without opening it.

  • PHI GENESIS - Multi-tech scanning XPS/HAXPES
    The PHI GENESIS offers a variety of optional in-situ analytical methods such as HAXPES, UPS, LEIPS, AES, and REELS. Options such as cluster ion beam, sample heating and cooling, external port for “an inter connection chamber” meet various needs....

  • Semiconductor devices generally consist of complex thin films containing many elements, and their development often requires non-destructive analysis of chemical states at interfaces.
    HAXPES is necessary to acquire information from buried interfaces such as GaN under gate oxide film.

    Features

    • Fully automated
    • Multi-tech XPS / HAXPES
    • Easy Operation & Multi-technique Options
    • High Performance Large & Micro Area XPS Analysis
    • High Speed & Non Destructive Depth Profiling
    • Fully Automated with Sample Parking
    • Hard X-ray Cr Kα source for HAXPES
    • Comprehensive solution for batteries, semiconductors, organic devices and other applications

  • LiteScope™ - AFM in SEM - Next level of imaging
    Atomic Force Microscope designed for easy integration into the Scanning Electron Microscopes. The combination of complementary AFM and SEM techniques enables you to use the advantages of both commonly used microscopy techniques....

  • Key added values

    • Complex sample analysis
      Unique technology of multidimensional correlative imaging enables simultaneous acquisition of data from SEM and AFM, and their seamless correlation into 3D images.
    • In-situ conditions
      All measurements are done at the same time, in the same place and under the same conditions, preventing the need of sample transfer and risk of contamination during analyses.
    • Precise localization of the region of interest
      Extremly precise and time saving approach using SEM to localize and navigate the AFM to the region of interest.

    Key benefits

    • Enhancement of SEM capabilities
      AFM in SEM enhances the capabilities of both techniques, enabling complex sample analysis of electrical, mechanical and magnetic properties inside SEM.

    • Ultimate precision of correlative imaging
      Unique Correlative Probe and Electron Microscopy (CPEM) technology enables simultaneous acquisition and correlation of the chosen SEM and AFM channels. 

    • Fast & easy localization of region of interest
      SEM helps to quickly localize the region of interest and to precisely navigate the AFM tip.

    • In-situ analysis - no risk of sample contamination 
      In-situ conditions inside the SEM ensure sample analysis at the same time, in the same place and under the same conditions. 

    • Extension of 2D SEM image into 3D
      SEM material contrast is enhanced by the information about sub-nanometer 3D topography and roughness.

    Graphene_SiC_AFMvsCPEM


Send Email