Loading...

Shanghai Chang Ai Technology & Development Co.,Ltd.

WP KUALA LUMPUR,  WP KUALA LUMPUR 
Malaysia
https://en.ci-ele.com/about.shtml
  • Booth: 3416

Welcome to Chang Ai Technology Exhibition Booth!

Overview

Chang Ai Technology, a Shanghai-based high-tech enterprise, is deeply involved in gas standardization and analysis. Since its establishment in 2004, it has excelled in sensor and instrument development, becoming a key player in China's industrial gas sector. The company's rapid growth is attributed to its focus on high-tech research, leading to innovative products and industry-standard contributions. With a wide range of patented technologies and a commitment to quality management under ISO9001 standards, Changai Technology has diversified into various sectors, including environmental protection, metallurgy, petrochemicals, and more. Its products, exported to over 20 countries, are renowned for their reliability and precision. Moving forward, the company aims to expand globally while maintaining its dedication to technological advancement and customer satisfaction.


  Products

  • CI-PC129 Trace Oxygen Analyzer
    CI-PC129 Trace Oxygen Analyzer is able to meet the requirements of fast response and high precision control in industrial process monitoring....

  • Sensor: Electrochemical

    Measuring Range: 0~10/100/1000/1%/25.00% O2

    Linear Error: 

    • 0.01~9.99ppm O2: ±5%FS

    • 10.0~99.9ppm O2: ±3%FS

    • 100~1000ppm O2: ±2%FS

    Repeatability:

    • 0.01~9.99ppm O2: ±2.5%FS

    • 10.0~99.9ppm O2: ±1.5%FS

    • 100~1000ppm O2: ±1%FS

    Stability:

    • 0.01~9.99ppm O2: ±2.5%FS/7d

    • 10.0~99.9ppm O2: ±1.5%FS/7d

    • 100~1000ppm O2: ±1%FS/7d

    Response time:  T90<60s(25°C)

    Power Supply: AC 100~240V, 50/60Hz

    Communication: RS485 (standard)/RS232 (optional)

    Ambient Temperature: 0~+45°C

    Ambient Humidity: <80%RH

    Switching Signal: 1 group, 4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V, can set the mode freely, Load: <500Ω

  • CI-PC1208 Multi-channel Oxygen Analyzer
    Specially made for the semiconductor industry, CI-PC1208 is equipped with a multi-channeled display that is able to capture up to 12 channels of Oxygen concentration readings with high precision and reliability....

  • Principle: Ion Flow

    Measuring Range: 0~25.00% O2

    Linear Error:

    • 0.01~99.9ppm ±10ppm
    • 100~999.9ppm ±3%FS
    • 1000~9999ppm ±3%FS
    • 1.00~25.00%  ±3%  of measured value

    Repeatability:

    • 0.01~99.9ppm ±5ppm
    • 100~999.9ppm ±1.5%FS
    • 1000~9999ppm ±1.5%FS
    • 1.00~25.00%  ±1.5%  of measured value

    Stability:

    • 0.01~99.9ppm ±5ppm/7d
    • 100~999.9ppm ±1.5%FS/7d
    • 1000~9999ppm ±1.5%FS/7d
    • 1.00~25.00%  ±1.5% /7d of measured value

    Response Time: T90<60s (after full preheating)

    Background Gas: N2, He, Ar and other inert gases, excluding Si, Pb, and Hydrocarbons

  • GEN-25 Portable Dewpoint Analyzer
    The GEN-25 Portable Dewpoint Analyzer is made for easy sampling purposes. With the large capacity lithium battery it has built in, GEN-25 is able to achieve a standby time of more than 48 hours....

  • Principle: Ultra-thin Alumina Capacitive

    Measuring Range:

    • -60°C~+20°C (basic)
    • -80°C~+20°C (standard)
    • -100°C~+20°C (extension)

    Linear Error: 

    • ±3°C (-80°C~-60°C)
    • ±2°C (-60°C~+20°C)

    Repeatability: ±0.5°C

    Zero Drift: ±1%FS/7d

    Range Drift: ±1%FS/7d

    Response Time: 63%[90%] range at +20°C and 1 bar

    • -60°C~+20°Ctd 5s[10s]
    • +20°C~-60°Ctd 45s[10min]

    Power Supply: AC 100~240v, 50/60Hz

    Consumption: <20VA

    Connection Port: DB-15 Female

    Ambient Temperature: 0~+45°C

    Ambient Humidity: <80%RH

    Sample Gas Pressure: Atmospheric Condition ±10% (Gas outlet should be atmospheric conditions)

  • CI-FT211 Thermal Mass Flowmeter
    CI-FT211 is designed based on thermal measurement technology. It can measure standard flow, mass flow consumption, and gas temperature directly. It has no moving parts, stable signal, vibration proof, high reliability, and long-term measurement accuracy....

  • Principle: Thermal Mass

    Measuring Range: 0(0.1)~250Nm/s

    Accuracy: ±(1.5% RD + 0.3%FS) [1% RD Accuracy optional]

    Sampling Rate: >20 sample points per second

    Medium: Compressed Air, Nitrogen, Oxygen, Carbon Dioxide and other Non-condensable gases

    Reference Conditions: 20°C, 1 bar(a) - ISO1217 (editable)

    Analog Signal (standard): 4-20mA (isolated)/pulse output (total)

    Digital Output (standard): Modbus RTU (RS485)

    Wireless Output: Bluetooth connection (standard), Lora (optional)

    Connector: 2×5pin M12, female

    Working Pressure: FT211: 0~6.3MPa (<1.6MPa needs to be equipped with high pressure installation shelf)

    Power: DC 18~30V/5W@DC24V

  • CI-PC9300 Online Gas Chromatography
    CI-PC9300 is a desk-type Online Gas Chromatograph develop by Chang Ai Technology. Using the automatic sampling system, the instrument can optionally be equipped with various detectors according to different application requirements....

  • Detector Type

    Thermal Conductivity Detector (TCD)

    • Detection Object: ppm-% impurities in gas
    • Detection Limit: 10ppm
    • Carrier Gas Type: N2/Ar/He
    • Carrier Gas Flow: 100ml/min

    Hydrogen Flame Ionization Detector (FID)

    • Detection Object: ppm-% hydrocarbon impurities in gas
    • Detection Limit: 0.03ppm
    • Carrier Gas Type: N2/Ar
    • Carrier Gas Flow: 100ml/min

    Pulse Discharge Ammonic Ionization Detector (PDHID)

    • Detection Object: ppb level trace impurities in high purity gas
    • Detection Limit: 5ppb
    • Carrier Gas Type: He
    • Carrier Gas Flow: 150ml/min

    Plasma Detector (PED)

    • Detection Object: ppb level trace impurities in high purity gas
    • Detection Limit: 0.5ppb
    • Carrier Gas Type: N2/Ar/He/CO2
    • Carrier Gas Flow: 150ml/min

    Gas Path Control

    Sample Gas Flow: Positive Pressure: 50ml/min or negative pressure sampling

    Sample Gas pressure: -0.1MPa ~ 0.1MPa

    Sample Gas Interface: 1/4

    Carrier Gas Pressure: 5 ~ 30 PSIG

    Flow Control: Electronic Monitoring

    Electrical Appliance

    Power Supply: AC220V, 50/60Hz

    Consumption: 400W

    Communication Interface: RS232/485, TCP

    Protocol: Modbus-RTU, Modbus-TCP, 4-20mA

    Shape

    Dimension: Standard 5U Rack-mount Chassis

    Temperature Control Parameters

    Temperature Control Area: 8 ways

    Temperature Control Range: Above room temperature 4°C ~ 450°C, increment: 1°C, Accuracy: ±0.01°C

    Program Heating Steps: 20 steps

For Technical Support with this webpage, please contact support.