Clamp-On Ultrasonic Flowmeters-FM800H Series
COMPARISION
Traditional Costs
- Maintenance: Shutdown,Disassembly,Cleaning,Calibration,Installation,Fastening,Sealing,Start-up
- Start-up: Start-up operation, resume production
- Sealing: Implement sealing measures to prevent leakage
- Fastening: Use flanges, threads, etc., to ensure the flowmeter is securely fastened to the pipeline.
- Installation: Install the flowmeter in the designated position.
- Pipe cutting: On-site construction involving pipe cutting, requiring complex safety certifications.
- Shutdown: Shut down the fluid supply in the pipeline, halting production.
- Flowmeter: Product and material costs
FM800H Cost Saving
- Maintenance:Calibration,Installation
- Installation:Install the flowmeter in the designated position
- Flowmeter:Product and material costs
Clamp-on Measurement
- 1. No need for pipe cutting or shutdown
- 2. No pressure loss or contamination
- 3. No risk of leakage or contamination
- 4. Adaptable to various pipes,including metal,plastic,hoses
- 5. Easy installation and setup.
READING ACCURACY: ±2.5% Turn Down ratio: 20:1 Repeatability: ±0.5%
Technical Features
V-method Measurement
The sensor transmits and receives on the same side, with reflections occurring on the inner wall of the pipe, increasing the sound path, which helps to improve time resolution.
AGC+VGA
Technology AGC + VGA dual gain technology, adapted to more challenging operating conditions.
Screen Rotation
The screen is rotatable, allowing operators to obtain the best reading angle on-site, whether the pipe is horizontal or vertical.
Filtering Algorithm
BICCNS employs a unique filtering and fusion algorithm that effectively overcomes pulse interference,enhances signal stability,and improves measurement accuracy.
Solid Coupling Technology
Solid coupling technology replaces the traditional silicone oil coupling method,achieving truly maintenance-free operation over the long term.
ACS technology: Automatic sound speed correction
With BICCNS's automatic sound speed adaptation solution, real-time on-site sound speed calculation and correction can be achieved, compensating for sound speed variations and improving the accuracy of flow measurement.
Extremely Low Output Discharge Volume
Achieves an extremely low flow output with a minimum instantaneous flow rate of 0.1 mL/min and a minimum discharge volume of 0.001 mL.
IO-Link Communication
As an IO-Link manufacturer and community member, we support IO-Link communication technology, which can provide process data, diagnostic data, and device information. These data and information can be read or written via the IO-Link protocol. In certain cases, parameters can be changed during operation through a stacked PLC.
Further Technical Specifications can be seen on the brochure
or
download this on our website(http://en.baiconsensor.com)