Perseus™
A bipolar pulsed generator that can produce waveforms on a wafer surface for improved ion energy distribution (IED) control compared to traditional RF or pulsed DC. The voltage, pulse width, pulse frequency, and burst patterns are all user controlled. Active energy recovery offers high-efficiency operation at high average power.
- Ion energy distributions produced by Perseus™ are close to monoenergetic, allowing for ultimate control over the electrode’s bias, which can lead to better selectivity and improved features at high aspect ratios.
- No matching network is required.
Perseus™ is an ideal choice for building out new state-of-the-art 300 mm processing facilities or retrofitting older 200 mm systems.
Tunable Ion Energy Distributions (IEDs)
Using only measurements internal to the power supply, an estimated IED can be calculated by the controller or other devices communicating with Perseus™ in real-time or post-process. This data can be used for precise control over the process in terms of ion energy, rather than power delivered to the plasma. Because the ion energy distribution for an individual pulse is very tight, and the voltage on the electrode is easily adjusted, unlimited IEDs can be generated over the duration of a process run, tailored to achieve specific process results.
Output Voltage Control (Multistate)
Output voltage can be adjusted on two timescales. For pulse-to-pulse adjustments, the pulse width can be reduced, which charges the load capacitance to a lower voltage. On longer timescales, the external DC supply set point can be changed.
Controller Options
An optional EHT controller allows for TCP/IP (EHTnet) or EtherCAT control. Other industrial protocols can be rapidly developed if needed. Alternatively, the pulse width and pulse repetition frequency can be controlled directly via fiber and an external signal generator.
Specifications
+Vout, pos. pk, max
|
11 kV+
|
+Vout, pos. pk, min
|
<25 V
|
Vout, pk-pk, max
|
17 kV
|
Velectrode voltage profile
|
Load dependent, calculated in real-time
|
DC input power
|
25 kW
|
DC Supply
|
External, 208 VAC 3-Φ, or 480 VAC 3-Φ input
|
Aux. AC Input Power
|
120 VAC 1-Φ
|
Pulse Repetition Frequency (PRF)
|
300 kHz – 600 kHz
|
Burst Repetition Frequency (BRF)
|
100 Hz – 100 kHz
|
Burst Duty Cycle
|
1 – 100%
|
Minimum Burst Length
|
5 µs @ 400 kHz PRF
|
Number of States
|
Unlimited
|
State Transition Time
|
5 µs @ 400 kHz PRF
|
Output Connection
|
Customizable. Options include: 3 m+ coaxial cable, direct connection
|
Communication Protocol
|
EHTnet, EtherCAT, TCP/IP
|
Dimensions, switching module (DxWxH)
|
31.2” x 21.4” x 19.5” (79.4 cm x 54.4 cm x 49.5 cm)
|
Dimensions, external DC supply
|
4U, 19” rack-mount
|
Cooling
|
Water, 3.0 GPM, 16 – 35 °C (switching module)
Water, 3.0 GPM, 25 °C max (DC supply)
|