LNEYA致力于为半导体行业提供精确的温度控制解决方案。作为冷却器开发和生产的全球行业领导者,我们为各种半导体工艺提供温度控制设计,包括但不限于以下工艺:光刻、蚀刻、CVD、PVD、清洗、测试和封装等。我们的客户遍布全球各个国家和地区。请随时联系我们了解更多详情。

了解更多关于https://www.lneya-online.com


  Press Releases

  • During semiconductor manufacturing, many key processes require the use of chillers to provide precise temperature control to ensure process stability, consistency, and yield. Here are some semiconductor processes that rely heavily on chillers:

    1. Photolithography
    Requirement:

    The photolithography machine generates a lot of heat during the exposure process, especially when using deep ultraviolet (DUV) or extreme ultraviolet (EUV) light sources. Chillers are needed to cool the light source, optical system, and wafer stage to maintain stable exposure conditions.

    Temperature control requirements: Temperature fluctuations must be controlled within ±0.1°C to ensure uniform exposure and pattern accuracy of the photoresist.

    2. Etching

    Dry etching:

    During plasma etching, the electrodes and reaction chambers generate a lot of heat. Chillers are used to cool the electrodes and chambers to maintain stable plasma conditions and etching rates.

    Wet etching:

    The temperature of the chemical solution needs to be precisely controlled to ensure etching rate and uniformity. Chillers are used to cool or heat chemical baths.

    3. Chemical Vapor Deposition (CVD)

    In the CVD process, the reaction chamber and wafer need to be kept within a specific temperature range to control the deposition rate and quality of the film. The chiller is used to cool the reaction chamber, gas delivery system and heater.

    Temperature control requirements: Temperature stability must be within ±0.5°C to ensure the uniformity and performance of the film.

    4. Physical Vapor Deposition (PVD)

    In the PVD process, the sputtering target and chamber generate heat. The chiller is used to cool the target and chamber to maintain stable deposition conditions.

    Temperature control requirements: Temperature fluctuations must be controlled within ±1°C.

    5. Ion Implantation

    Ion implanters operate under high pressure and high energy conditions, which generates a lot of heat. The chiller is used to cool the ion source, accelerator and wafer stage to ensure stable operation of the equipment and process consistency.

    Temperature control requirements: Temperature stability must be within ±0.5°C.

    6. Chemical Mechanical Polishing (CMP)

    During the CMP process, friction heat is generated between the polishing pad and the wafer. The chiller is used to cool the polishing liquid and the polishing pad to control the polishing rate and surface flatness.

    Temperature control requirements: Temperature fluctuations must be controlled within ±1°C.

    7. Diffusion

    The diffusion furnace operates at high temperatures, but some components (such as the cooling chamber) need to be cooled. The chiller is used to cool the auxiliary systems of the diffusion furnace to ensure process stability.

    Temperature control requirements: Temperature stability must be within ±1°C.

    8. Cleaning

    During the wafer cleaning process, the temperature of the chemical solution needs to be precisely controlled. The chiller is used to cool or heat the cleaning liquid to ensure the cleaning effect and wafer surface quality.

    Temperature control requirements: Temperature fluctuations must be controlled within ±1°C.

    9. Testing and Packaging

    During the wafer testing and packaging process, the test equipment and packaging equipment generate heat. The chiller is used to cool the test probe station, packaging mold and other key components.

    Temperature control requirements: Temperature stability must be within ±1°C.

    10. Other auxiliary equipment

    Other equipment in semiconductor manufacturing, such as vacuum pumps, lasers, and gas delivery systems, also requires cooling. Chillers are used to maintain stable operation of these equipment.

  • The semiconductor industry has extremely high requirements for temperature control, especially in wafer manufacturing, packaging testing, lithography, etching, ion implantation and other links. Slight changes in temperature will affect product yield and process stability. The following are several main temperature control solutions:

    1. Liquid circulation temperature control

    Principle: Accurately adjust the temperature of the equipment or process by circulating cooling liquid or heating liquid (such as water, oil, fluorinated liquid, etc.).

    Application: lithography machine, etching machine, CVD/PVD equipment, wafer detection equipment, etc.

    Typical solution:

    Circulating cooling system (Chiller): Use coolant to adjust the temperature.

    Heat exchange system: Use heat exchanger to control temperature gradient.

    2. Thermoelectric cooling (TEC, Peltier cooling)

    Principle: Based on the Peltier effect, semiconductor materials are used to convert heat and cold under the action of electric current.

    Application: Precision optical equipment, detectors, lasers, wafer detection systems, etc.

    Advantages:

    Precise temperature control (within ±0.1°C).

    No need for refrigerant, environmentally friendly.

    Small size, fast response speed.

    3. Electric heating solution

    Principle: Rapid heating by means of resistance heating, infrared heating, induction heating, etc.

    Application:

    Rapid Thermal Processing (RTP): Rapid heating of silicon wafers to improve material properties.

    CVD/PVD equipment: Temperature control during chemical vapor deposition (CVD) or physical vapor deposition (PVD).

    Wafer testing: Precise temperature control is required during chip testing.

    4. Gas temperature control

    Principle: Uniform temperature control is achieved by controlling the temperature of nitrogen, helium or other inert gases.

    Application:

    Plasma etching: Stable temperature control of the process chamber.

    Lithography machine: Temperature control of the lens and mask.

    Wafer handling system: Prevent condensation or thermal expansion caused by temperature changes.

    5. Phase change temperature control

    Principle: Use phase change materials (such as paraffin, alloys, etc.) to absorb or release heat to achieve constant temperature control.

    Application:

    Equipment with extreme temperature stability requirements.

    Storage of materials that require constant temperature, such as photoresists and chemical reagents.

    6. Vacuum environment temperature control

    Principle: Reduce heat transfer interference and improve temperature control accuracy through vacuum insulation or internal heat source regulation.

  • Water chillers are critical for semiconductor packaging testing, where precise temperature control is required to ensure the reliability and performance of packaged semiconductor devices. During testing, devices are subjected to thermal cycling, burn-in, and other stress tests to validate their functionality and durability. Here are the key considerations for selecting a water chiller for semiconductor packaging testing:


    1. Temperature Control Precision and Stability

    • Precision: Semiconductor testing often requires temperature control within ±0.1°C or better to ensure accurate and repeatable test results.
    • Stability: The chiller must maintain stable temperatures to prevent fluctuations that could affect test outcomes or damage sensitive devices.

    2. Cooling Capacity

    • Heat Load: Calculate the heat load generated by the testing equipment, including thermal chambers, burn-in boards, and device power dissipation.
    • Capacity: Choose a chiller with sufficient cooling capacity (in kW or BTU/hr) to handle the maximum heat load during testing.

    3. Temperature Range

    • Operating Range: Semiconductor packaging testing typically requires chillers that can operate in a wide range, from -40°C to 95°C or higher, depending on the test requirements.
    • Sub-Ambient Cooling: Many tests require sub-ambient cooling to simulate low-temperature conditions.

    4. Flow Rate and Pressure

    • Flow Rate: Ensure the chiller can provide the required flow rate (in liters per minute or gallons per minute) to effectively remove heat from the testing equipment.
    • Pressure: Verify that the chiller can maintain the necessary pressure to circulate coolant through the system, especially in high-resistance setups.

    5. Coolant Type

    • Compatibility: Use a coolant that is chemically compatible with the materials in the testing equipment (e.g., stainless steel, copper, or aluminum).
    • Thermal Properties: Choose a coolant with high thermal conductivity and low viscosity for efficient heat transfer.
    • Common Coolants: Deionized water, water-glycol mixtures, or specialized heat transfer fluids.

    6. Energy Efficiency

    • High Efficiency: Select a chiller with energy-efficient components, such as variable-speed compressors and pumps, to reduce operating costs.
    • Heat Recovery: Some chillers offer heat recovery options, which can be used to preheat other parts of the system or facility.

    7. Integration with Testing Equipment

    • Control Interface: Ensure the chiller can integrate with the testing equipment's control interface (e.g., PLC, SCADA) for seamless operation.
    • Communication Protocols: Look for chillers that support standard communication protocols like Modbus, Profibus, or Ethernet/IP.

    8. Reliability and Redundancy

    • Reliability: Choose a chiller from a reputable manufacturer with a proven track record in semiconductor or testing applications.
    • Redundancy: For critical testing processes, consider redundant chillers or backup systems to prevent downtime in case of failure.

    9. Noise and Vibration

    • Low Noise: Testing environments often require low noise levels to avoid interference with sensitive measurements.
    • Vibration Control: Ensure the chiller has minimal vibration to avoid mechanical disturbances during testing.

    10. Maintenance and Serviceability

    • Ease of Maintenance: Choose a chiller with accessible components (e.g., filters, pumps, and heat exchangers) for easy maintenance.
    • Service Support: Ensure the manufacturer provides reliable technical support and spare parts availability.

    11. Environmental and Safety Considerations

    • Eco-Friendly Refrigerants: Select chillers that use environmentally friendly refrigerants (e.g., R-134a, R-513A).
    • Safety Features: Look for chillers with built-in safety features such as over-temperature protection, low coolant level alarms, and pressure relief valves.

    12. Compliance with Industry Standards

    • Certifications: Ensure the chiller complies with relevant industry standards, such as CE, UL, or ISO.
    • Cleanroom Compatibility: If used in a cleanroom, the chiller should meet cleanroom standards for particulate and contamination control.

    13. Customization Options

    • Application-Specific Needs: Some testing processes may require custom chillers with specific cooling capacities, flow rates, or temperature ranges.
    • Compact Design: For space-constrained environments, consider compact or modular chiller designs.

  Products

  • Semiconductor Chillers
    Our temperature control equipment ensures highly accurate and constant temperatures in the manufacturing process of electronic components and semiconductors....

  • Website: https://www.lneya-online.com/

    • Efficient and energy-saving: The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user's cold and hot load requirements through a built-in variable frequency device, maintaining the stable working state of the unit and achieving energy-saving effects.
    • Tewmperature control range: -120℃ to +300℃, ±0.03 high precision control.
    • Fast cooling: The frequency conversion unit adopts advanced frequency conversion technology to accurately control the operating speed of the compressor and fan.
    • Ultra low noise: The variable frequency unit adopts a variable frequency vortex or dual rotor compressor, greatly reducing the imbalance of the rotation and making the vibration of the unit very small.
    • High environmental adaptability: The variable frequency unit adopts low-frequency starting, with a small starting current. Strong adaptability to voltage.
    • Long lifespan: The variable frequency unit will not tart and stop frequently, effectively reducing losses during unit start and stop and extending unit lifespan.
  • Gas Chillers
    Gas temperature controlled chillers for semiconductor industry, various types of gas chillers for you to choose from....

  • Website: www.lneya-online.com

    LNEYA develops and produces high performance gas chiller used whenever high precise temperature control and rapid temperature changes are required. By adapting new technologies and innovations to maintain top reliability level worldwide, all production steps are focused to offer high quality and customized solutions to meet any requirement.

  • AES Temperature Forcing Systems
    Accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment....

  • Website: www.lneya-online.com

    • Temperature range: -120 ℃ ~ +300 ℃.
    • The temperature rise and fall is very fast, -55 ℃ ~ 150 ℃ < 10 seconds.
    • Temperature control accuracy: ±1 ℃.
    • Temperature setting capability: ±0.1 ℃.
    • Temperature display capability: ±0.1 ℃.
    • Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time.
    • The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.